Skip to product information
1 of 1

Action Can LD-90 Gas Leak Detector

Action Can LD-90 Gas Leak Detector

Water-based gas leak detector identifying pipeline and valve leaks through visible bubble formation on all gas types including oxygen systems.

SKU:1754592

In stock

⚙ Ideal For

  • Gas and air pipeline leak detection
  • Heating system commissioning checks
  • Automotive air-conditioning testing
  • Oxygen and specialised gas systems
  • Low-pressure system verification

✔ Benefits

  • Highlights non-visible leaks instantly
  • Water-based, non-flammable safety
  • Solvent, silicone, and oil-free
  • Works on low-pressure systems
  • Oxygen-system compatible formulation
DETAILED DESCRIPTION →
Regular price £9.99 GBP
Regular price Sale price £9.99 GBP
£8.33 Ex. VAT
Sale Sold out
Taxes included. Shipping Policy
Quantity

🚚 UK Shipping: Standard (£2.99) or FREE on orders over £75.

📦 Dispatched same-day if ordered before 3pm!

Shipping Information

What Are My Shipping Options?

In-Store Pickup

In-Store pickup is available on all purchase. Pickups are available Monday - Friday between the hours of 9:00–17:00. 

An email confirmation will be sent when your order is ready for collection. 

Free Shipping

We offer free Standard (2-3 Days) shipping on orders within the United Kingdom on orders over £100. Please note, some large items that require specialist courier companies, such as large mirrors and palleted items are excluded from this deal.

Shipping Fees

We also offer shipping at the following rates:

Standard-Size Parcel

Standard (UK Only) - 2-3 Days - £2.99

Express (UK Only) - 1-2 Days - £4.99

International (EU) - 3-7 Days - £14.99

International (ROW) - 5-10+ Days -£23.99


Large Parcel

Standard (UK Only) - 2-3 Days - £2.99

Express (UK Only) - 1-2 Days - £4.99

International (EU) - 3-7 Days - £14.99

International (ROW) - 5-10+ Days - £69.99

Most UK orders will be sent using Royal Mail, with larger items being sent with DPD.

International orders within the EU will normally be dispatched with Royal Mail, DPD, or UPS.

International orders to the rest of the world will normally be sent with DPD or UPS.

Please note, international delivery charges are very volatile and subject to change. We will do everything in our power to honour the delivery fee, however, in some cases, shipping may increase in price. In this event, you will be given the offer to pay the difference or cancel the order and receive a full refund.

Please note, we may be subject to various rules and restrictions in relation to some international deliveries, and you may be subject to additional taxes and duties over which we have no control. If such cases apply, you are responsible for complying with the laws applicable to the country where you live and will be responsible for any such additional costs or taxes.

Dispatch Times

Orders placed before 15:00 Monday - Friday will be shipped on the same day. 

Orders placed after this time will be shipped on the following business day,

Please note, we are closed at weekends, as well as English Bank Holidays.

Returns Policy

Our refund policy can be found at the following address: https://esupplyline.com/policies/refund-policy.

Further Information

You can contact us for further information on our shipping policies using the following:

Phone: 01953 711 881

Email: sales@esupplyline.com

Live Chat: Available on our website, Monday - Friday, 8:30 - 17:00.

Contact Form: https://esupplyline.com/pages/contact

View full details

Action Can LD-90 Gas Leak Detector

Action Can LD-90 is a professional-grade water-based gas leak detector engineered to safely identify leaks in pipework, valves, and fittings on all gas types. The non-flammable, solvent-free formulation forms highly visible bubbles at leak locations, revealing even non-visible leaks on low-pressure systems. Conforming to BS EN 14291:2004 and MIL-L-25567 standards, LD-90 serves gas fitting, plumbing, heating, HVAC, and automotive air-conditioning applications.

Key Features

  • Instant Bubble Formation — Forms highly visible bubbles precisely at leak locations, providing immediate visual confirmation of gas or air escape.
  • Low-Pressure System Detection — Effective on low-pressure systems where many detectors fail, identifying leaks that would otherwise remain hidden.
  • Oxygen System Compatible — Formulated to MIL-L-25567 standards for safe use on oxygen systems and other specialised gases without introducing contamination.
  • Non-Flammable Water-Based Chemistry — Water-based formulation eliminates flammability hazards, safe for use on live gas systems and around ignition sources.
  • Solvent, Silicone, and Oil-Free — Absence of solvents, silicones, and oils prevents contamination of gas systems or subsequent coating processes.
Free UK Delivery On all orders over £75
Secure Payment SSL Encrypted Checkout
Trade Trusted Premium Quality Brands
100% Genuine Direct from Manufacturer

Description

Gas System Leak Detection Challenges

Gas leaks represent serious safety hazards—undetected leaks create flammability risks, oxygen depletion concerns, and system inefficiency. Visual inspection alone is inadequate; many leaks are non-visible even when present. Traditional leak detection methods require expensive equipment, extended downtime, or invasive system modifications. LD-90 addresses these challenges through chemistry that creates immediate visible confirmation of leaks through simple spray application.

Bubble Formation Chemistry for Leak Identification

LD-90's water-based formulation creates a surfactant solution that forms stable bubbles when exposed to escaping gas or air. The bubbles persist long enough for visual inspection, but deflate immediately upon gas cessation, eliminating false positives. This bubble mechanism is far more reliable than dye detection or electronic sniffers, providing visual proof rather than interpretation.

Low-Pressure System Capability

Many commercial leak detectors fail on low-pressure systems—insufficient pressure creates no visible reaction. LD-90's formulation is specifically optimised for low-pressure detection, identifying leaks on systems operating at pressures below 1 bar where conventional products would fail. This low-pressure capability extends leak detection to HVAC systems, air lines, and low-pressure hydraulic assemblies.

Oxygen System Compatibility and Safety

Oxygen systems present unique challenges—contamination risk and flammability concerns eliminate many cleaning and detection products. LD-90's MIL-L-25567 compliance ensures oxygen-system safety. The formulation introduces no contamination risk; residues are simply water that evaporates or can be rinsed away. This oxygen compatibility expands leak detection capability to aircraft, medical, and industrial oxygen systems.

Non-Flammable Application Safety

Traditional solvent-based leak detectors present flammability hazards near ignition sources, pilot lights, or spark-prone environments. LD-90's non-flammable water-based formulation eliminates this hazard, allowing safe application in any environment—around welding operations, pilot lights, or heated systems. This safety profile is essential for heating engineers and gas fitters working on operational systems.

Economical Multi-Application Versatility

Beyond gas leak detection, LD-90 serves multiple applications—air line inspection, water system verification, industrial pressurised system testing. This versatility eliminates the need for specialty detectors for each gas type or application. A single product serves diverse leak detection needs across industrial, automotive, HVAC, and plumbing applications.

More Information

Application Instructions

Ensure electrical equipment is turned off before testing. De-energise control systems and ignition sources to eliminate sparks or ignition hazards.

Verify the gas system is pressurised and functional. The system must be under pressure for leak detection—atmospheric or depressurised systems show no leaks.

Identify areas requiring leak inspection. Plan testing to cover critical junctions, valves, regulators, joints, and connection points.

Shake the LD-90 container well before use. Mix thoroughly to ensure uniform liquid consistency.

Select appropriate application method. Use TwinSpray for ergonomic application or standard aerosol based on convenience and access requirements.

Spray LD-90 evenly over the area to be tested. Apply a light, continuous mist across the entire surface area under inspection.

Observe for bubble formation indicating leaks. Bubbles will appear immediately at any leak location where gas or air escapes.

Mark leak locations for documentation. Identify and note all leak locations observed; photograph for records if required.

Verify leak location by bubble cessation. Once spray application ceases, bubbles will deflate if no gas escape is occurring—confirming genuine leak identification.

Repeat testing on additional areas. Systematically test all connections, valves, and potential leak points in the system.

For oxygen systems, wash with water after testing. On oxygen equipment, rinse away LD-90 residue with water to prevent any residue accumulation.

Document findings for maintenance records. Record leak locations, severity, and areas inspected for system maintenance and compliance documentation.

Specifications

Product Type Water-based professional gas and air leak detector

Format Aerosol spray, TwinSpray

Container Sizes 500 mL aerosol, 500 mL TwinSpray

Appearance Clear, colourless liquid

Odour Odourless

Specific Gravity at 20°C 1.00

pH 8.5

Surface Tension 28 mN/m

Solubility Soluble in water; insoluble in solvents

Foam Stability 90% (DIN 53902)

Corrosion Profile Not corrosive (DIN 30657)

Primary Function Gas and air leak detection

Secondary Functions System pressure verification, joint integrity testing

Detection Method Bubble formation at leak locations

Leak Targets Gas pipes, valves, regulators, fittings, joints, cylinders, air lines, air brakes

Gas Compatibility All types of gases including oxygen (O₂)

System Pressure Range Effective on low-pressure systems; minimum pressure for bubble formation depends on system type

Application Method Aerosol spray creating mist coverage

Formulation Water-based, non-flammable

Chemical Composition Surfactant solution without solvents, silicones, or oils

Contamination Risk Zero contamination risk; water-based residue only

Standards Compliance BS EN 14291:2004 (VOSA MOT Testing); MIL-L-25567 (oxygen system compatibility)

Safety Profile Non-flammable, safe for use near ignition sources and operational heating systems

Oxygen System Safety Specifically formulated for oxygen system use; residue wash-off recommended

Industrial Applications Gas fitting, plumbing, heating, HVAC, automotive air-conditioning, welding, QC testing, maintenance and safety checks

Bubble Persistence Forms stable bubbles at leaks; deflates upon gas cessation

False Positive Risk Low—genuine leak confirmation through bubble persistence

Storage Temperature Normal ambient; below 50°C for aerosols

Shelf Life Minimum 6 years with proper storage

Market Sectors Engineering, trade/pro-DIY, utilities

HS Code 3402.20

FAQs

How quickly does LD-90 form bubbles after detection of a leak, and how long do bubbles persist?

Bubbles form almost immediately upon LD-90 contact with escaping gas or air—typically within 1–3 seconds. Bubble persistence depends on leak size and gas pressure; larger leaks produce more vigorous bubbling that persists throughout gas escape. Once gas cessation occurs, bubbles deflate immediately, providing clear confirmation that the detected location is a genuine leak rather than a false positive from residual moisture.

Can LD-90 be used on all types of gases, including oxygen systems and specialty gases?

Yes. LD-90 is specifically formulated for compatibility with all gas types including oxygen, nitrogen, argon, and other specialised gases. The MIL-L-25567 compliance ensures oxygen-system safety. However, on oxygen systems, rinse away residue with water after testing to prevent any residue accumulation. For other gas types, no special precautions are required beyond standard safety protocols.

Does LD-90 require special equipment or training to use, or can any technician apply it?

LD-90 requires no special equipment or training—spray application is straightforward. Simply shake the container and spray the area under inspection. Anyone with basic understanding of the system being tested can apply LD-90. However, interpretation of results and appropriate action on detected leaks should be performed by qualified technicians familiar with the system design and safety requirements.

Will LD-90 leave residue that could contaminate the gas system or interfere with future testing?

LD-90 is water-based with zero contamination risk to gas systems. The water residue either evaporates naturally or can be rinsed away with water if residue is a concern. On oxygen systems specifically, water rinse-off is recommended to prevent residue accumulation. For non-oxygen systems, no residue concern exists; LD-90 leaves no chemical contamination or film that would interfere with future testing or system operation.

Your cart
Product Product subtotal Quantity Price Product subtotal
Action Can LD-90 Gas Leak Detector1754592
Action Can LD-90 Gas Leak Detector1754592
£9.99/ea
£0.00
£9.99/ea £0.00